Richmond Hill Attic Insulation & Air Sealing handles attic duct sealing and insulation in Richmond Hill, with our energy specialists testing every duct system before recommending a fix. Plenty of homes here run heating, air conditioning or HRV ducts through the attic, especially bungalows with added central air and newer builds with an upstairs air handler. When those ducts leak or sit bare in a freezing attic, you end up paying to heat and cool the space above your ceiling instead of the rooms below.
What goes into every duct system we seal and insulate:
Most of our duct sealing and insulation jobs in Richmond Hill run $800 to $2,500, depending on the length of the duct runs and their condition. Jobs that replace all the flex duct can reach $4,000. Every job starts with a free inspection and a written quote from us.
Upstairs rooms always the hottest in summer and the coldest in winter? Call us, and we’ll find out how much of your heating and cooling is ending up in the attic.


The back bedrooms of this 1970s bungalow, a few minutes from Elgin West Community Centre, ran hot all summer and cold all winter after central air was added through the attic. In the 1,150 sq ft attic, the flex duct was crushed over the joists, torn in one run and taped loosely to its ceiling boots.
Our Richmond Hill Attic Insulation & Air Sealing crew replaced it with R-8 insulated duct hung on wide straps, brushed mastic over every joint and wrapped the metal trunk in foil-faced insulation.
The second Duct Blaster test showed leakage cut from 31% to under 8%.
Turnaround Time: 1 day
Final Price: $3,300
Richmond Hill Attic Insulation & Air Sealing runs a blower door test on every home before any work begins.
The fan depressurizes the house so our technicians can measure how leaky it really is and where the air escapes.
The test runs again after installation, and both results are recorded for you to keep.
Since 2005, our crews have worked through older homes, non-standard attic layouts and tricky ventilation setups.
That adds up to 500+ attic projects across Richmond Hill and the GTA, with 150+ completed in 2026 alone.
A 97% client satisfaction rate shows the work holds up long after the crew leaves.
Every install follows Ontario Building Code standards, with R-values suited to freeze-thaw winters and summer heatwaves.
Before we start, you receive a written scope, confirmed material specs and a clear timeline.
A written warranty then covers both the materials and our workmanship.
A 4-person crew finishes most attics in 4 to 8 hours, so your day stays close to normal.
Hoses feed straight into the attic to keep dust out of your living space, and cleanup and haul-away are included.
The balance is only due after a senior supervisor walks through the finished attic with you.
We’ll call you back within 2 business days to book your free inspection.


Leaking supply ducts release conditioned air into the attic before it reaches registers, forcing the HVAC system to run longer and contributing to temperature differences between rooms. Leakage commonly occurs at metal seams, branch takeoffs, collars, elbows, and transitions where tape has failed or joints were never sealed properly. Sealing these connections helps keep conditioned air inside the duct system.
Richmond Hill Attic Insulation & Air Sealing locates accessible joints and uses mastic, foil tape, approved duct sealants, clamps, or mechanical fasteners according to the surface and gap. Our technicians remove loose insulation from connection points, stabilize separated sections, and seal the joint without restricting the duct opening. Damaged metal, crushed flex duct, or a poorly fitted transition may require replacement before insulation is installed.
Return-side leaks can draw dusty attic air into the HVAC system and reduce the volume of air returning to the equipment. Gaps around return plenums, filter racks, air handlers, trunk connections, and access panels can also pull air from the attic when the blower operates. These defects require careful sealing because return ducts operate under negative pressure.
Our technicians inspect plenums, sheet-metal seams, filter housings, return boxes, and equipment connections for gaps, loose fasteners, dust trails, and damaged sealant. Richmond Hill Attic Insulation & Air Sealing uses mastic, foil tape, gasket materials, and compatible insulation around the return assembly while preserving filter access and equipment service clearances. Contaminated or deteriorated duct components may need cleaning, repair, or replacement before sealing.


Duct insulation replacement improves thermal protection when existing wrap is missing, compressed, wet, torn, or too thin for the attic conditions. Exposed supply ducts can lose heating or cooling energy as they cross unconditioned space, while damaged insulation can create condensation on cold duct surfaces. New insulation must fit tightly without blocking dampers, access panels, fire-rated components, or service points.
Richmond Hill Attic Insulation & Air Sealing evaluates duct diameter, surface temperature, existing wrap, vapor-retarder condition, moisture exposure, and clearance from roofing and electrical components. Our technicians install compatible duct insulation, secure seams, and repair the outer jacket so the system remains protected during attic maintenance. Wet insulation or corroded ductwork must be corrected at the source rather than covered with new material.
Flexible duct can lose airflow when it sags, kinks, compresses against framing, or contains excessive bends. Poorly supported flex duct also places stress on collars and connections, creating leakage and reducing delivery to the register. Rerouting may be necessary when the existing path prevents proper insulation coverage or creates a severe airflow restriction.
Our technicians check the inner liner, insulation jacket, support straps, radius at bends, connection collars, and termination boots. Richmond Hill Attic Insulation & Air Sealing replaces damaged sections or establishes a cleaner route where the duct cannot be restored in its current position. Limited attic clearance, truss webs, plumbing, wiring, and existing insulation determine the access method and final duct layout.

01
Our technicians begin by identifying supply branches, return paths, plenums, trunks, transitions, register boots, equipment connections, and accessible joints throughout the attic. We examine duct size, material, insulation coverage, airflow symptoms, dust accumulation, condensation, and visible separation. This mapping shows where leakage and thermal loss are most likely to affect HVAC performance.
Attic access, low clearances, roof framing, electrical wiring, recessed fixtures, and ventilation components are documented before materials are moved or ductwork is disturbed. Richmond Hill Attic Insulation & Air Sealing uses these findings to separate accessible sealing from sections requiring duct repair, rerouting, or replacement. The condition of each run determines the next preparation step.
02
Loose insulation, dust, failed tape, damaged jackets, and debris are removed from the joints selected for sealing. Our technicians align separated collars, tighten fasteners, support sagging flex duct, and expose enough surface for mastic, foil tape, clamps, or other compatible materials to bond correctly. Preparation matters because sealant applied over unstable or contaminated joints can fail.
Existing damage changes the scope when a liner is torn, a metal section is corroded, or a transition does not match the duct diameter. Richmond Hill Attic Insulation & Air Sealing identifies these conditions before covering the connection with insulation. Sections that can be stabilized proceed to sealing, while defective components are repaired or replaced first.
03
We apply duct sealant to seams, takeoffs, plenums, collars, boots, and transitions, then install or replace insulation around exposed ductwork. They secure insulation seams and outer jackets while preserving access to dampers, filters, equipment panels, and other service components. The selected insulation must remain intact in the attic environment and avoid contact with heat-producing fixtures or obstructed ventilation paths.
Duct routing and clearance determine whether a wrap, insulated flex section, rigid insulation assembly, or reroute is appropriate. Richmond Hill Attic Insulation & Air Sealing coordinates the installation with existing attic insulation and air sealing without crushing the duct or concealing unresolved leaks. Moisture-damaged insulation is removed or corrected rather than sealed beneath a new layer.
04
After sealing and insulation, our technicians review connections, supports, outer jackets, insulation continuity, access panels, and register boots. They look for remaining gaps, compressed duct sections, exposed surfaces, loose straps, blocked components, and conditions that could continue to restrict airflow or cause condensation. This review confirms whether the completed work matches the identified duct defects.
Findings from the review determine whether minor adjustments, additional sealing, duct rerouting, or component replacement is needed. Richmond Hill Attic Insulation & Air Sealing documents unresolved limitations caused by inaccessible areas, equipment condition, or existing duct design instead of treating the installation as complete without qualification. The final scope reflects the actual performance and condition of the attic duct system.
Yes, attic ducts should be sealed before they are insulated because insulation cannot correct leaking joints, open seams, disconnected collars, or damaged plenums. Our technicians clean and stabilize accessible connections, apply compatible mastic or foil tape, and then install insulation over serviceable duct sections. Richmond Hill Attic Insulation & Air Sealing replaces defective duct components before covering them so leaks are not hidden beneath the new insulation.
Yes, attic duct sealing can improve uneven heating or cooling when leakage, crushed flex duct, disconnected branches, or poorly insulated runs reduce airflow to specific rooms. Our technicians inspect the affected branch, register boot, transition, support straps, and insulation before determining whether sealing alone is sufficient. Richmond Hill Attic Insulation & Air Sealing also identifies design limitations, blocked registers, and damaged duct sections that may require correction beyond joint sealing.
Attic duct insulation should be replaced when it is missing, wet, compressed, torn, detached, contaminated, or unable to protect the duct surface in the attic. Our technicians inspect the insulation jacket, vapor retarder, duct temperature, moisture marks, and nearby roof or plumbing conditions before selecting replacement material. Richmond Hill Attic Insulation & Air Sealing corrects the source of wet insulation and preserves access to dampers, filters, and equipment panels during installation.
No, attic duct sealing is not suitable for every HVAC system without evaluating duct material, equipment compatibility, access, clearance, and component condition. Our technicians inspect sheet-metal ducts, flex duct, plenums, transitions, return assemblies, and heat-producing equipment before choosing sealants and insulation. Incompatible materials, restricted clearances, severely damaged ductwork, or inaccessible joints may require component replacement or a revised installation method.
Warning signs include rooms that remain too hot or cold, weak register airflow, excessive HVAC runtime, dusty air from return leaks, condensation on ducts, damaged insulation, and visible gaps at collars or plenums. Our technicians trace these symptoms through the accessible duct system and check for sagging flex duct, crushed sections, open seams, and disconnected branches. Richmond Hill Attic Insulation & Air Sealing uses the findings to recommend sealing, insulation replacement, support repairs, rerouting, or duct replacement.